Tuesday, December 3, 2013

Water Softener Drain Line Air Gap

Water Softener Drain Line Air Gap Pictures

2401 SOFTENER VALVE
Location: The water softener and control cannot be exposed to outdoor elements, such as direct sunlight or atmospheric precipitation. • Run the drain line to the air gap. Note: There must be a GAP-A-Flow (for floor drains), Mr. Drain (for stand ... Retrieve Doc

Water Softener Drain Line Air Gap Photos

Cross Connections And Water Softeners - Minnesota Department ...
Placing the softener discharge drain line into a sink without an air gap. How to provide a proper air gap for backflow prevention Air gaps are a non-mechanical means of backflow prevention. Water Softener Discharge Line Unprotected Protected. ... Retrieve Full Source

Images of Water Softener Drain Line Air Gap

Installation Requirements - EcoPure Water Products
AIR GAP REQUIREMENTS A drain is needed for regeneration water (See Figure 3). A floor drain, close to the water softener, is mm drain line (provided) to the water softener valve drain fitting. Use a hose clamp to hold the hose in place. ... Get Content Here

Washing Machine - Wikipedia, The Free Encyclopedia
Extreme overloading can also push fabrics into the small gap between the underside of While the consumer models pump used washer water out, allowing the waste line to be located above the washer, front loading commercial machines generally use only gravity to expel used water. A drain in ... Read Article

Water Softener Drain Line Air Gap Images

RAINFRESH EDSE WATER SOFTENERS.
WASTE WATER DRAIN. A PHYSICAL AIR GAP OF AT LEAST 3" SHOULD BE USED TO AVOID BACTERIA AND WASTEWATER TRAVELING BACK THROUGH THE DRAIN LINE INTO THE SOFTENER. Install the salt tank by using the 3/8" tubing (provided) and locating the brine valve that accepts the tubing on the ... Doc Viewer

Water Softener Drain Line Air Gap Images

EN WATER SOFTENER - ERIE Water Treatment
Located at the back side of the water softener; secure 4. Run the drain hose to the sewerage system and connect it to the stand pipe assuring sufficient air gap. This drain line does NOT operate under pressure, so it may NOT be installed higher than the water softener. Picture 5 ... Return Document

Water Softener Drain Line Air Gap Images


Sanitary sewer line Connection to sanitary sewer line (optional) Air gap device Drain line 1/2” diameter minimum size Drain Trap It is recommended that outside faucets for lawn service be on the hard water line, ahead of the softener, to conserve softened water, save salt and prevent lawn ... Retrieve Full Source

Uploads From Pakwater Care Services - YouTube
Water Softener System Engineering of fresh water / waste water treatment plants along with the air pollution control system to provide entire The reject water exits the vessel and feed the next vessel or is sent to drain. The product water exits the vessel and is sent to a ... View Video

Photos of Water Softener Drain Line Air Gap

INSTALLATION INSTRUCTIONS - Watts Water Technologies ...
Need to be designed to prevent water damage caused by a catastrophic failure condition. Do not reduce the size of the drain line from the air gap fitting. NOTICE Drain funnel was not designed to, nor is it able to support drainpipe weight. ... Read Document

Pictures of Water Softener Drain Line Air Gap

Softener WS1 Startup - Residential Well Water Treatment, Iron ...
Clack WS1 Water Softener Installation Guide WS1 Softener Installation & Start‐Up Guide Thank you for purchasing a Clean Water The drain line tubing plumbing codes require an air‐gap connection, so that if your sewer or septic tank backs up , it ... Fetch Doc

Water Softener Drain Line Air Gap

DLA-G TM Multipurpose Airgap DRAIN INE DAPTER
DLA-G Multipurpose Airgap DRAIN LINE ADAPTER The DLA-G multipurpose standpipe airgap is designed for residential and commercial water softeners and RO’s. ... Retrieve Content

Water Softener Drain Line Air Gap

Installing Your Fleck Water Softener - Quality Water Treatment
You always leave an air gap if going into a pipe. An air gap is an open area where there is no standing water. Your drain line can be elevated up to 5 feet over and above Filling your softener with water and purging air from softener: ... Retrieve Doc

Water Softener Drain Line Air Gap Photos

Installing A Water Softener - Drain - About.com Plumbing
When installing a water softener you will need a drain for the unit to drain into. Remember to allow an air gap when between the drain hose and the drain when installing a water softener. Page 4. ... Read Article

Pictures of Water Softener Drain Line Air Gap

Water Softener Installation
As your water softener sends water to drain during each regeneration cycle. If possible, the drain should be no farther than 20 feet from the softener. Note: Never connect the drain line directly into a drain. Allow an air gap between ... Read Full Source

Photos of Water Softener Drain Line Air Gap

G.A. Murdock Drain II Air Gap
Drain II Air Gap Adapter Drain II Air Gap Adapter Item # Material Top Port(B) Side Port (C) M3208007 White PVC 1/2” Mur-lok® None 1/2”, 5/8” ID water softener drain line • Connects to 1/4”, 3/8”, 1/2” OD RO drain line ... Read Document

Venturi Effect - Wikipedia, The Free Encyclopedia
Sand blasters used to draw fine sand in and mix it with air; Emptying bilge water from a moving boat through a small waste gate in the hull—the air pressure inside the moving boat is greater than the gap between the Twin Towers of the original World Trade Center was an extreme example ... Read Article

Pictures of Water Softener Drain Line Air Gap

SPECIFICATION SHEET Series 601-P - Watts Water Technologies ...
To be designed to prevent water damage caused by a catastrophicfailure condition. Do not reduce the size of the drain line from the air gap fitting. NOTICE Discharge of drain funnel is a slip fit design. ... Read Here

Water Softener Drain Line Air Gap Pictures

PLUMBING & CROSS-CONNECTION CONTROL - Alabama Department Of ...
The soap portioner must contain an internal air gap. I. Water wash system for an exhaust hood (self cleaning): Provide an air gap between the end of the supply line and the floor drain or floor sink. (The supply line water still remains as part of the supply system as it cools. ... Fetch Here

Water Softener Drain Line Air Gap Pictures

WATER SOFTENER
Connect the water supply to the inlet of the water softener ( ). DRAIN To prevent backflow from the sewerage system into the water softener, always make sure to have an air gap between the end of the drain line and the sewerage system itself; This drain line operates under pressure, ... Document Retrieval

Water Softener Drain Line Air Gap Photos

The Noncom Scoop - Minnesota Department Of Health
Drainage of the softener discharge drain line to a floor drain with out an air gap. 3. Placing the softener discharge drain line into a sink without Proper installation of a drain line from a water softener, showing air gap. ... Read Document

Water Softener Drain Line Air Gap

Water Softener Discharge2 - Kalamazoo Michigan County ...
Water softener discharge line air “gap” connection to sewer line An air gap protects your water supply Water softener di h d Alternate methods for water softener discharge Water softener discharged via an air gap to a floor drain not connected to septic tank … or drywell ... View This Document

Water Softener Drain Line Air Gap Pictures

Installation Requirements - EcoPure Water Products
Air gap FLOOR DRAIN In the state of Massachusetts: Adrain is needed for regeneration water (See Figure 3). Afloor drain, close to the water softener, is pre-ferred. A laundry tub, standpipe, etc. are other drain options. Secure valve drain hose in place. Leave an Make the valve drain line as ... View Document

Water Softener Drain Line Air Gap Pictures

Family And Your - NeRWA
1. Check your water softener or other in -home treatment device to insure that any drain lines have a proper air gap prior to entering the sewer line. ... View Document